Product Overview
The Fluke 719 100G is a portable, electric pressure calibrator with a built-in pump, designed for calibrating pressure-to-current transmitters and featuring programmable limit settings, included hoses, and test leads, along with a printed product overview manual and a user manual on CD-ROM in 14 languages.
The Fluke 719 100G is a portable, electric pressure calibrator designed for precise calibration of pressure-to-current transmitters. It features a built-in electric pump, enabling easy pressure generation with one hand. The device supports a pressure range of 100 psi (7 bar) and includes programmable pump limit settings to prevent over-pressurization. Accessories like TL75 hoses and test leads are provided, along with a printed product overview manual and a user manual on CD-ROM in 14 languages for comprehensive setup guidance.
1.2 Key Features and Benefits
The Fluke 719 100G Pressure Calibrator offers advanced features such as compatibility with Fluke 700 Series Pressure Modules, ensuring seamless integration with existing systems. It includes test leads with alligator clips for secure connections. The handheld design enhances portability, making it ideal for fieldwork. The device also features programmable pump limit settings to prevent over-pressurization, ensuring accurate calibration every time. Additionally, the Fluke 719 100G supports multiple languages in its user manual, making it accessible to a global user base. Its intuitive interface simplifies the calibration process, reducing the learning curve for new users.
Key Features and Technical Specifications
The Fluke 719 100G features a 100 psi (7 bar) pressure range, built-in electric pump, and compatibility with Fluke 700 Series modules, ensuring precise calibration and portability.
2.1 Pressure Range and Accuracy
The Fluke 719 100G offers a pressure range of 100 psi (7 bar) with an accuracy of 0.05% full-scale, ensuring precise calibration for pressure-to-current transmitters and other devices; It supports gauge and vacuum pressure measurements, providing versatility for various industrial applications. The device delivers reliable performance across its range, making it ideal for maintaining instrument accuracy in process control and calibration tasks. Its precision ensures consistent results, meeting the demands of professional calibration environments.
2.2 Built-in Electric Pump and Portability
The Fluke 719 100G features a built-in electric pump, enabling easy pressure generation and calibration without external sources. Its portable design allows for one-handed operation, ideal for fieldwork. The device is lightweight and compact, making it simple to transport to various locations. The electric pump eliminates the need for manual pumping, streamlining calibration tasks and enhancing efficiency. This portability, combined with its intuitive controls, ensures quick and accurate pressure calibration in diverse industrial environments, making it a versatile tool for professionals on the go.
2.3 Programmable Pump Limit Settings
The Fluke 719 100G features programmable pump limit settings, allowing users to set maximum pressure limits to prevent over-pressurization during calibration. This customizable feature enhances safety and efficiency by restricting the pump’s output to the desired range. The settings are easy to adjust via the device’s interface, ensuring precise control over pressure generation. This functionality is particularly useful for applications requiring specific pressure thresholds, making the calibrator versatile for diverse industrial and field calibration needs while maintaining operational safety and accuracy.
Installation and Setup
Unpack and inspect the Fluke 719 100G, ensuring all components are included. Connect the pressure module to the sensor port, then power on the device, following the display prompts for initialization.
3.1 Unpacking and Initial Inspection
Begin by carefully unpacking the Fluke 719 100G Pressure Calibrator. Verify the contents, including the calibrator, TL75 hose, test leads, and manuals. Inspect all items for damage or defects. Ensure the device and accessories are complete and undamaged. Familiarize yourself with the components before proceeding to setup. This step ensures readiness for operation and calibration tasks.
3.2 Connecting the Pressure Module
Plug the Fluke Pressure Module into the sensor port of the Fluke 719 100G. The display will change to show dashes momentarily before displaying a pressure value. Ensure the module is securely connected for accurate measurements. This step is essential for enabling the calibrator to function properly. Always verify the connection before proceeding with calibration tasks to ensure reliable operation and precise results. Proper connection is critical for maintaining accuracy and performance.
3.3 Powering On the Device
Press the power button to turn on the Fluke 719 100G. The display will illuminate, and the device will perform a self-test. Ensure the battery is fully charged or connect to a power source if needed. Once powered on, the calibrator is ready for operation; Always refer to the user manual for detailed instructions on startup procedures and power management to ensure optimal performance and accuracy during calibration tasks. Proper power initialization is essential for reliable functionality.
Operating the Fluke 719 100G
The Fluke 719 100G is a portable, easy-to-use electric pressure calibrator with a built-in pump, designed for precise pressure calibration and featuring programmable settings for efficient operation.
4.1 Basic Operation and Calibration Process
Operating the Fluke 719 100G involves connecting the pressure module to the sensor port, which triggers the display to initialize. Users can then utilize the programmable pump limit settings to prevent over-pressurization. The calibration process includes setting target pressures, adjusting values, and verifying accuracy. The built-in electric pump allows for one-handed operation, simplifying fieldwork. The device also supports calibrating pressure-to-current transmitters efficiently, ensuring precise results with minimal effort.
4.2 Using the Electric Pump for Pressure Generation
The Fluke 719 100G features a built-in electric pump, enabling easy pressure generation without external tools. Simply power on the device, set the desired pressure using the interface, and the pump automatically adjusts to reach the target. This portability and simplicity make it ideal for fieldwork. The pump’s operation is smooth and quiet, ensuring accurate pressure calibration. Users can also program limits to prevent over-pressurization, enhancing safety and efficiency during operation.
4.3 Navigating the User Interface
The Fluke 719 100G features an intuitive user interface designed for simplicity and efficiency. The display provides clear pressure readings and menu options, while buttons allow easy navigation through calibration settings. Users can quickly access features like zero adjustments and programmable pump limits. The interface is designed to minimize complexity, ensuring seamless operation during calibration tasks. Its user-friendly design makes it accessible for both novice and experienced professionals, streamlining the calibration process and reducing downtime.
Calibration Procedures
The Fluke 719 100G enables precise calibration of pressure-to-current transmitters with programmable pump limits and zero adjustments, ensuring accurate and efficient pressure calibration processes.
5.1 Calibrating Pressure-to-Current (P/I) Transmitters
The Fluke 719 100G simplifies the calibration of P/I transmitters by providing precise pressure control. Connect the transmitter, set the desired pressure using the electric pump, and adjust the current output to match the pressure value. The device ensures accurate calibration by allowing users to fine-tune settings and verify performance. This process is efficient and reliable, making it ideal for maintaining transmitter accuracy in industrial environments. The programmable pump limits help prevent over-pressurization, ensuring safe and consistent results.
5.2 Adjusting Pressure Limits and Settings
Adjusting pressure limits on the Fluke 719 100G ensures safe and accurate calibration. Use the menu to set maximum and minimum pressure thresholds, preventing over-pressurization. Navigate to the “Limits” menu, select “Pressure Limit,” and input the desired value using the keypad. The device confirms the adjustment, ensuring settings are correctly applied. This feature is essential for customizing the calibrator to specific applications, maintaining precision, and protecting equipment from excessive pressure. Properly configured limits enhance both safety and calibration efficiency.
5.3 Performing Zero Adjustments
Zero adjustments on the Fluke 719 100G ensure accurate pressure measurements. Access the “Zero Adjust” menu, then press “Enter” to initiate the process. The device will prompt you to vent the system to atmospheric pressure. Once vented, confirm the adjustment. The display will show “0.000” when complete, indicating successful zero calibration. Regular zero adjustments maintain precision and reliability in pressure calibration tasks, ensuring measurements remain consistent and trustworthy over time.
Maintenance and Troubleshooting
Regularly clean the device and inspect hoses for wear. Troubleshoot common issues like pump malfunction or display errors by referring to the user manual for solutions.
6.1 Routine Maintenance Tips
Regular maintenance ensures optimal performance of the Fluke 719 100G. Clean the device and connectors with a soft cloth and mild detergent. Inspect hoses for signs of wear or damage and replace them if necessary. Check the electric pump for proper operation and ensure all connections are secure. Verify calibration accuracy periodically and adjust if needed. Store the calibrator in a dry, cool environment to prevent damage from moisture or extreme temperatures.
6.2 Troubleshooting Common Issues
Troubleshooting the Fluke 719 100G involves addressing common issues like display errors or pump malfunctions. If the display shows no reading, ensure the pressure module is securely connected. For pump issues, check for blockages or worn seals. If the device fails to power on, verify battery charge or power cord connections. Consult the user manual for detailed diagnostic steps. Regular calibration and maintenance can prevent many common problems, ensuring accurate and reliable performance.
Accessories and Compatibility
The Fluke 719 100G is compatible with Fluke 700 Series Pressure Modules, ensuring seamless integration. It works with various Fluke test equipment, enhancing its versatility in calibration tasks.
7.1 Included Accessories (Hoses, Test Leads, etc;)
The Fluke 719 100G Pressure Calibrator comes with a range of essential accessories, including a high-quality TL75 hose for secure connections, test leads with alligator clips for reliable electrical connections, and a printed product overview manual. Additionally, a detailed user manual is provided on a CD-ROM in 14 languages, ensuring comprehensive guidance for global users. These accessories enhance the device’s portability and ease of use, making it a complete solution for pressure calibration tasks.
7.2 Compatibility with Other Fluke Products
The Fluke 719 100G Pressure Calibrator is designed to integrate seamlessly with other Fluke instruments and accessories, such as the 700 Series Pressure Modules and test leads, ensuring enhanced functionality and versatility. Its compatibility with Fluke’s ecosystem allows users to leverage existing tools and software, streamlining calibration processes and improving efficiency. This interoperability makes it an ideal choice for professionals already utilizing Fluke equipment in their workflows.
Safety Precautions
Always wear protective gear and follow guidelines when handling high-pressure systems. Ensure the device is properly grounded and avoid over-pressurization to prevent accidents during operation.
8.1 General Safety Guidelines
Always wear appropriate protective gear, including safety goggles and gloves, when operating the Fluke 719 100G. Ensure the device is properly grounded to prevent electrical hazards. Avoid over-pressurization by setting limits according to the manual. Keep the work area clean and well-ventilated. Regularly inspect hoses and connections for damage. Follow all safety warnings and instructions provided in the user manual. Never bypass safety features or ignore alarm signals. Ensure proper training before operating the calibrator to avoid accidents and ensure accurate calibration results.
8.2 Handling High-Pressure Systems
When working with high-pressure systems, ensure all connections are secure to prevent leaks or equipment damage. Use the programmable pump limit settings to avoid over-pressurization, as specified in the manual. Always employ appropriate hoses and adapters rated for the pressure range. Wear safety goggles and gloves to protect against potential fluid discharge. Follow the user manual’s guidelines for high-pressure applications to ensure safe and accurate calibration. Regularly inspect hoses and connections for wear or damage before use.
User Manual and Documentation
The Fluke 719 100G includes a printed product overview manual and a user manual on CD-ROM, available in 14 languages, ensuring comprehensive guidance and accessibility.
9.1 Overview of the User Manual
The user manual for the Fluke 719 100G provides detailed instructions for installation, operation, and maintenance. It includes sections on calibration procedures, troubleshooting, and technical specifications. The manual is available in 14 languages, ensuring accessibility for a global user base. Key topics covered include pressure-to-current transmitter calibration, programmable pump limit settings, and safety guidelines. The manual also features a table of contents, safety precautions, and appendices for quick reference. It is provided on a CD-ROM for convenient access and digital storage.
9.2 Understanding the Product Overview Manual
The product overview manual provides a concise introduction to the Fluke 719 100G, highlighting its key features and applications. It includes a printed guide that covers basic operation, pressure calibration, and programmable pump limit settings. Designed for quick reference, the manual helps users understand the device’s capabilities and accessories, such as hoses and test leads. It complements the detailed user manual, offering a streamlined overview to familiarize users with the product before diving into advanced procedures.
Warranty and Support
The Fluke 719 100G is backed by a comprehensive warranty and dedicated customer support. For details on warranty terms and contact information, refer to the manual.
10.1 Warranty Information
The Fluke 719 100G Pressure Calibrator is protected by a comprehensive warranty that covers defects in materials and workmanship. The standard warranty period is typically one year from the date of purchase, but extended warranty options may be available. For specific details, including terms and conditions, refer to the product manual or contact Fluke support. Proper registration and maintenance are recommended to ensure warranty coverage remains valid. Fluke’s commitment to quality ensures reliable performance and customer satisfaction.
10.2 Contacting Fluke Support
For assistance with the Fluke 719 100G, contact Fluke support through their official website or the contact information provided in the user manual. The manual includes details for regional support centers, ensuring prompt service. Fluke’s support team is available to address technical queries, repair requests, and warranty-related issues. Visit Fluke’s website for live chat, email options, or phone support, depending on your location. Their dedicated team ensures reliable and professional assistance for all product-related needs.
Comparison with Other Models
The Fluke 719 100G offers higher pressure capacity compared to the 719 30G, making it suitable for applications requiring up to 100 psi or 7 bar pressure.
11.1 Fluke 719 30G vs. 100G
The Fluke 719 100G offers a higher pressure range of 100 psi (7 bar) compared to the 30G model, which is limited to 30 psi (2 bar). While both models share similar features like portability, a built-in electric pump, and programmable limit settings, the 100G is better suited for high-pressure applications. The 30G, however, is ideal for lower-pressure environments, making it a cost-effective option for users with specific calibration needs. Both models include accessories like hoses and test leads, ensuring versatility and convenience.
11.2 Key Differences and Use Cases
The Fluke 719 100G is designed for high-pressure applications up to 100 psi (7 bar), making it ideal for industrial environments. In contrast, the 719 30G is suited for lower-pressure applications up to 30 psi (2 bar), catering to smaller-scale systems. Both models share features like portability and programmable pump limits but differ in pressure capacity. The 100G is recommended for heavy-duty calibration tasks, while the 30G is perfect for precision in lower-pressure settings, ensuring optimal performance in their respective use cases.
The Fluke 719 100G is a portable, high-precision pressure calibrator with advanced features like a built-in electric pump, programmable settings, and compatibility with multiple modules. Ideal for professionals needing accurate calibration in industrial settings, it combines ease of use with robust functionality, making it a reliable choice for pressure calibration tasks.
12.1 Summary of the Fluke 719 100G
The Fluke 719 100G is a portable, high-precision electric pressure calibrator designed for calibrating pressure-to-current transmitters. It features a built-in electric pump, programmable pump limit settings, and compatibility with Fluke 700 Series Pressure Modules. The device is user-friendly, with a compact design that allows one-handed operation. Included accessories such as test leads, hoses, and a user manual in 14 languages enhance its versatility. It is an ideal tool for professionals requiring accurate and efficient pressure calibration in various industrial applications.
12.2 Final Thoughts and Recommendations
The Fluke 719 100G is a top-tier pressure calibrator, offering exceptional ease of use, versatility, and reliability for industrial applications. Its built-in electric pump and programmable settings make it ideal for professionals needing precise calibration. With its portability and user-friendly design, it is highly recommended for those requiring efficient and accurate pressure calibration. Fluke’s commitment to quality and comprehensive support further enhance its value, making it a standout choice in its category.